4.Exit the Serial Port Selection and Configuration mode: Press and release an output button.

All Control buttons and the Output 31 (71) and Output 32 (72)

Press and release buttons return to unlit or background illumination. an output button.

 

C O N T R O L

 

 

5

ENTER PRESET

VIEW

ESC

31 32

 

 

 

 

 

Reset Operations

The rear panel has a Reset button that initiates four levels of resets (numbered 1, 3, 4, and 5 for the sake of comparison with an Extron IPL product). The Reset button is recessed, so use a small screwdriver, a pointed stylus, or a ballpoint pen.

For different reset levels, press and hold the button while the switcher is running or press and hold the button while you apply power to the switcher.

See the table on the next page for a summary of the modes.

ATTENTION: Review the reset modes carefully. Using the wrong reset mode may result in unintended loss of flash memory programming, port reassignment, or a controller reboot.

NOTE: The reset modes listed on the next page close all open IP and Telnet connections and close all sockets. Also, the following modes are separate functions, not a continuation from Mode 1 to Mode 5.