Maintenance and
Modifications
This section provides procedures for maintaining and modifying the FOX Matrix Switchers, including:
•Mounting the Switcher
•Battery and Power Precautions
•Removing and Installing the I/O Board or Blank Panel
•Removing and Installing the Power Supply Module
•Removing and Installing a Fan Module
•Removing and Installing Button Labels
ATTENTION: Installation and service must be performed by authorized personnel only.
Mounting the Switcher
The matrix switcher is housed in a
•FOX Matrix 3200 — 4U high
•FOX Matrix 7200 — 8U high
UL Guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the installation of the matrix switcher into a rack.
•Elevated operating ambient temperature — If the equipment is installed in a closed or
•Reduced air flow — Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
•Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition.
•Circuit overloading — Consider the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Use appropriate consideration of equipment nameplate ratings when addressing this concern.
•Reliable earthing (grounding) — Reliable earthing of