Switcher-initiated Messages

When a local event such as a front panel operation or an IR 501 command string occurs, the switcher responds by sending a message to the host. The switcher-initiated messages are listed below (underlined).

The switcher does not expect a response from the host, but, for example, the host program might request a new status.

(C)COPYRIGHT 20yy, Extron Electronics, FOX Matrix 3200, Vx.xx, 60-nnnn-01 {day,date, time}]

— or —

(C)COPYRIGHT 20yy, Extron Electronics, FOX Matrix 7200, Vx.xx, 60-nnnn-01 {day,date, time}]

The switcher initiates the copyright message when it is first powered on or when a connection via Internet protocol (IP) is established. Vx.xx is the firmware version number and 60-nnnn-01 is the switcher part number.

NOTE: {Day, date, time} are only reported if the connection is via the LAN port.

Password:]

The switcher initiates the password message immediately after the copyright message when the controlling system is connected using TCP/IP or Telnet and the switcher is password protected. This message means that the switcher requires an administrator or user level password before it will perform the commands entered via this link. The switcher repeats the password message response for every entry other than a valid password until a valid password is entered.

]Login Administrator]

]Login User]

The switcher initiates the login message when a correct administrator or user password has been entered. If the user and administrator passwords are the same, the switcher defaults to administrator privileges.

Qik]

The switcher initiates the Qik message when a front panel tie operation has occurred.

Sprnn]

The switcher initiates the Spr message when a memory preset has been saved from the front panel. “nn” is the preset number.

Rprnn]

The switcher initiates the Rpr message when a memory preset has been recalled from the front panel. “nn” is the preset number.

Vmtnn*x]

The switcher initiates the Vmt message when a channel output mute is toggled on or off from the front panel. nn is the output number and x is the mute status: 1 = on, 0 = off.

Exen]

The switcher initiates the Exe message when the front panel security lockout (executive mode) is toggled on or off from the front panel. “n” is the executive mode: 0 = unlocked, 1 = locked.