Extron electronic 7200, 3200 manual Direct write process, Reclocking, Laser controls

Models: 3200 7200

1 132
Download 132 pages 9.76 Kb
Page 68
Image 68

Command and Response Table for SIS Commands (continued)

Command Function SIS Command

Response

Additional description

(Host to Unit)

(Unit to Host)

 

 

 

 

Reclocking

 

 

NOTES:

Laser board reclockers are set on a per SFP basis. If an SFP is reclocked, the corresponding input and output reclockers reclock at the same rate.

HD-SDI reclockers are set on a per output basis only.

Set output reclocker

X$*X%=

RteX$*X%]

Example:

8*00=

Rte08*00]

Read reclocker status

X$=

X%]

Set the rate for reclocker X$ to X%. Set the rate for reclocker 8 to auto. Show current rate status for reclocker X$.

Laser controls

Enable individual laser driver

Disable individual laser driver Set individual output laser driver to automatic

Read status of all laser drivers

Global laser enable

EX!*1FIBR}

EX!*0FIBR} EX!*2FIBR}

EFIBR}

E1*FIBR}

FibrX!*1]

FibrX!*0]

FibrX!*2]

X^1X^2X^3X^4 ... X^n]

Fibr1]

Enable the laser for output X!. The laser lights so long as power is applied.

Disable the laser for output X!. The laser is off. Set the laser driver for output X! to automatic. The laser lights when a tie is made to output X!, but is off when no tie is made to output X! or the output is muted.

List the laser driver status of all installed outputs. n is the highest numbered output for your switcher. Enable all output laser drivers.

NOTE: If your switcher has any BNC 3G/HD/SD-SDI boards installed, the global commands are not available. The switcher returns E14.

Global laser disable

E0*FIBR}

Fibr0]

Disable all output laser drivers.

Global laser automatic

E2*FIBR}

Fibr2]

Set all output laser drivers to automatic.

Save, recall, and directly write global presets

NOTES:

If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.

The following characters are invalid or not recommended in preset names: + - , ` @ = [ ] { } ‘ “ ; : \ and ?.

Save current configuration

X&,

SprX&]

as a global preset

 

 

Example:

8,

Spr08]

Recall a global preset

X&.

RprX&]

Example:

5.

Rpr05]

Command character is a comma.

Save current ties as preset 8. Command character is a period.

Recall preset 5 (becomes the current configuration).

Direct write process

NOTE: The direct write of a global preset should always be preceded by a clear global preset ties command of that same preset number. In a directly-written preset, the tied input of each output position (or no tied input) remains unchanged unless overwritten or cleared.

If you do not clear the ties in a global preset number before you directly write a global preset to that number, ties that are part of the previous version of the specified preset with the same number can unexpectedly become part of the newly-created preset.

Clear global preset ties

E+X&P0*!}

 

 

 

 

SprX&]

Directly write a global preset

E+X&PX!*X@!X!*X@%X!*X@! ... X!*X@&}

 

 

 

 

 

 

 

 

 

SprX&]

Example:

E+27P0*!}

 

 

 

 

Spr27]

 

 

 

 

 

 

 

 

 

 

Esc

+27P12*5!10*09%3*2!3*8&

 

 

 

 

 

 

 

 

 

Spr27]

Clear all ties in preset X&.

Enter as many ties as are valid for this configuration. The ! tie, & tie, and % tie commands are all valid.

Clear all ties in preset 27.

Brackets are shown to separate ties for clarity only. Create global preset 27, which ties input 12 to output 5, input 10 to output 9, input 3 to output 2, and input 3 to output 8.

NOTE: X! = Input number (for tie)

00

– (maximum number of inputs for your configuration) (00 = untied)

X@ = Output number

01

– (maximum number of outputs for your configuration)

X$ = SFP or reclockable output

00 32 or 72 (00 = global [SFP only])

 

X% = Output reclocking rate

00

= Bypass mode

 

03 = 2.125 Gbps (laser boards only)

 

01

= Automatic mode (HDSDI boards only)

X^ = Laser control

02

= 1.250 Gbps (laser boards only)

04 = 4.250 Gbps (laser boards only)

0 = disable

1 = enable (default)

2 = automatic

X& = Global preset number

00

32 (FOX Matrix 3200) or 64 (FOX Matrix 7200) (00 = current configuration)

 

 

 

 

 

FOX Matrix 3200 and 7200 Switchers • Programming Guide 60

Page 68
Image 68
Extron electronic 7200 Direct write process, Reclocking, Laser controls, Save, recall, and directly write global presets