EView (<) button — The View (<) button has one primary function () and three secondary functions (•):

Select and indicate View-only mode, which displays the current configuration.

NOTE: View-only mode also provides a way to mute and unmute the outputs.

In the I/O Group mode, selects group 3 and indicates the selection.

With the Enter, Preset, and Esc buttons, selects Serial Port Selection and Configuration mode.

Selects 38400 baud for the rear panel Remote port in Serial Port Selection and Configuration mode, and indicates the selection.

FEsc (>) button — The Esc (>) button has two primary functions () and four secondary functions (•):

Cancels operations or selections in progress and resets the front panel button indicators.

NOTE: The Esc button does not reset the current configuration or any presets.

Flashes once to indicate that the escape function has been activated.

In the I/O Group mode, selects group 4 and indicates the selection.

With the Enter, Preset, and View buttons, selects Serial Port Selection and Configuration mode.

Selects 115200 baud for the rear panel Remote port in Serial Port Selection and Configuration mode and indicates the selection.

With the Enter button, toggles the front panel lock on or off.

Power Indicators

GPrimary and Redundant Power Supply LEDs

Green — Indicates that the associated power supply is operating within normal tolerances.

Red — Indicates that the associated power supply is operating outside the normal tolerances or has failed. See Removing and Installing the Power Supply Module on page 113 to replace the power supply.

FOX Matrix 3200 and 7200 Switchers • Operation 23