Viewing the Configuration

The current configuration can be viewed using the front panel buttons. The View-onlymode prevents inadvertent changes to the current configuration. View-onlymode also provides a way to mute outputs (see Muting and Unmuting Outputs on page 39).

View the current configuration as follows:

1.Press the Esc button to clear any front panel button indications that may be lit.

2.Press and release the View button. All of the buttons light for outputs that are not tied.

3.Select the desired input or output whose ties you wish to view by pressing the input or output buttons.

NOTES:

When you enter View-onlymode, the output buttons light for all outputs without ties. Likewise, when you press an output button for which there are no ties, the output buttons light for all outputs without ties.

To see all ties of the current configuration, press and release each input and output button, one at a time.

After 30 seconds of front panel inactivity, View-onlymode automatically deselects.

Example 4: Viewing ties

In the following example, we view the ties in the current configuration. The steps show the front panel indications that result from your actions.

NOTE: This example assumes that you have performed example 1 on page 27, example 2 on page 28, and example 3 on page 29.

1.Clear all selections: Press and release the Esc button.

2.Select View-onlymode: Press and release the View button. The View button lights.

Press the View button.

 

C O N T R O L

 

ENTER

PRESET

VIEW

ESC

The button lights.

Until you select an input, only the buttons for untied outputs light.

1 2 3 4 5 6 7 8 15 16

17 18 19 20 21 22 23 24 31 32

OUTPUTS

FOX Matrix 3200 and 7200 Switchers • Operation 31