Command and Response Table for SIS Commands (continued)
Command Function SIS Command | Response | Additional description |
(Host to Unit) | (Unit to Host) |
|
Information requests
Information request | I |
Slot/plane/LC information | 0*X1*I |
Request part number | N |
Request part number and | *N |
board configuration |
|
VX1%XX1^•AX1%XX1^•SX1&1X1&2...X1&n]
VX1%XX1^ shows the number of available inputs and outputs for this configuration.
AX1%XX1^ has no meaning for this product.
SX1&1X1&2...X1&n shows the board type installed in each slot.
n is either 4 or 9, depending on the model.
X1(1X1(2X1(3X1(4X1(5X1(6X1(7X1(8]
Part number (see below) plus I/O boards installed. n is either 4 or 9, depending on the model.
Read reclocker status | X$= | X%] | Show current rate status for reclocker X$. |
NOTE: The switcher automatically detects and reclocks the signal if the rate is 4.25 Gbps only. Other rates are ignored.
View SFP module status | 40*X2)S | X2!•X2@•X2#•X2$] |
NOTE: There are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is the overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware update, which is available at www.extron.com.
Query firmware version | Q | X2%] |
Example: | Q | 1.23] |
Query controller firmware | 0Q | |
version (verbose) |
|
|
The
Provide a detailed status of the Ethernet protocol firmware, the controller firmware, and any firmware upgrade. The firmware that is running is marked by an asterisk (*). A caret (^) indicates that the firmware has a bad checksum or an invalid load. ?.?? indicates that firmware is not loaded.
Response description: | Ethernet protocol firmware | |
Example: | 0q |
|
Description | * indicates the version running | Upload date and time |
![]()
|
|
|
|
|
|
|
|
|
|
| ||
| Ethernet |
| Fiber Matrix firmware version |
|
| Updated firmware version | ||||||
| protocol |
|
|
|
|
|
|
|
|
| ||
| firmware |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||||
NOTE: | X1% | = Number (quantity) of inputs | 8, 16, 24, 32, 40, 48, 56, 64, or 72 |
|
|
| ||||||
|
|
|
| X1^ = Number (quantity) of outputs | 8, 16, 24, 32, 40, 48, 56, 64, or 72 |
|
|
| ||||
|
|
|
| X1& = Board installed | 0 | = No board installed | 4 | = | ||||
|
|
|
|
|
| 1 | = | 5 | = | |||
|
|
|
|
|
| 2 | = | 6 | = Pathological singlemode board | |||
|
|
|
| X1* |
| 3 | = 3G, SDI, | X = Unknown board or mix of transceivers | ||||
|
|
|
| = I/O board slot number | 1 – 9 (FOX Matrix 7200) or 1 – 4 ( FOX Matrix 3200) |
|
| |||||
|
|
|
| X1( = Transceiver module installed | 0 | = No module installed |
|
|
| |||
|
|
|
|
|
| 1 | = | 3 | = | |||
|
|
|
| X2) = Transceiver module number | 2 | = | 4 | = Pathological singlemode module | ||||
|
|
|
| 01 – 72 (or maximum number of transceiver modules for your configuration) | ||||||||
|
|
|
| X2! = Vendor/manufacturer name |
|
|
|
|
|
|
| |
|
|
|
| X2@ = Transmit output power in milliwatts |
|
|
|
|
|
|
| |
|
|
|
| X2# = Receive optical power in milliwatts |
|
|
|
|
|
|
| |
|
|
|
| X2$ = SFP temperature | Degrees Celsius |
|
|
| ||||
|
|
|
| X2% = Firmware version number to second decimal place (x.xx) |
|
|
| |||||
|
|
|
| X2^ = Verbose firmware |
|
|
| |||||
|
|
|
| X% = Output reclocking rate | 00 = Bypass mode |
|
|
| ||||
|
|
|
|
|
| 01 = Automatic mode (HDSDI boards only) | 03 = 2.125 Gbps (laser boards only) | |||||
|
|
|
|
|
| 02 = 1.250 Gbps (laser boards only) | 04 = 4.250 Gbps (laser boards only) | |||||
|
|
|
| X$ = SFP or reclockable output number | 00 – 32 or 72 (00 = global [SFP only]) |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
FOX Matrix 3200 and 7200 Switchers • Programming Guide 65