The cable used depends on your network speed. The switcher supports both
10 Mbps
•
•
RJ-45 connector wiring
The Ethernet cable can be terminated as a
•Crossover cable — Direct connection between the computer and the FOX matrix switcher
•Patch (straight) cable — Connection of the FOX matrix switcher to an Ethernet LAN
Pins:
12345678
Insert Twisted
Pair Wires
RJ-45
Connector
Crossover Cable
| End 1 | End 2 |
Pin | Wire color | Wire color |
|
|
|
1 | ||
|
|
|
2 | Green | Orange |
|
|
|
3 | ||
|
|
|
4 | Blue | Blue |
|
|
|
5 | ||
|
|
|
6 | Orange | Green |
|
|
|
7 | ||
|
|
|
8 | Brown | Brown |
|
|
|
| T568A | T568B |
A cable that is wired as T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crossover" cable.
Pin | End 1 | End 2 |
Wire color | Wire color | |
|
|
|
1 | ||
|
|
|
2 | Orange | Orange |
|
|
|
3 | ||
|
|
|
4 | Blue | Blue |
|
|
|
5 | ||
|
|
|
6 | Green | Green |
|
|
|
7 | ||
|
|
|
8 | Brown | Brown |
|
|
|
| T568B | T568B |
A cable that is wired the same at both ends is called a
Figure 10. RJ-45 Connector and Pinout Tables
Reset Button and LED
E Reset button (see figure 3 on page 8 and figure 4 on page 9) — |
|
The recessed Reset button initiates four levels of matrix switcher reset. For four | RESET |
|
different reset levels, press and hold the button while the switcher is running or while you power up the switcher (see Reset Operations on page 43 for details).
•Events (mode 3) reset — Toggles events monitoring on and off.
•IP settings (mode 4) reset — Reset the IP functions of the switcher.
NOTE: The IP settings reset does not replace any
•Absolute (mode 5) reset — Restore the switcher to the default factory conditions.
•Hard reset — Restore the switcher to the default factory conditions and return the switcher to the default firmware that shipped with the unit.
NOTES:
•Factory loaded firmware is active until it is replaced or the power is cycled.
•Hard reset does not clear the current configuration.
FOX Matrix 3200 and 7200 Switchers • Installation 14