Command and Response Table for SIS Commands (continued)

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

Information requests (continued)

 

 

Request system status

S

 

 

FOX Matrix 3200 Response:

 

X2&•X2&•X2&•X2&•X2&•X2&•X2&•X2*•X2(•X2(]

FOX Matrix 7200 Response:

 

X2&•X2&•X2&•X2&•X2&•X2&•X2&•X2*•X2(•X2(•X2(•X2(]

Response description (FOX Matrix 3200):

+3.3V•+5V•+1.3V•+1.2V•+12V (fan volts)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan 1 RPM•Fan 2 RPM] Response description (FOX Matrix 7200):

+3.3V•+5V•+1.3V•+1.2V•+12V (fan volts)•+12V (redundant PS)•+12V (primary PS)•Temp•Fan 1 RPM•Fan 2 RPM•Fan 3 RPM•Fan 4 RPM]

 

 

 

Backplane receiving 12.00 V

Internal temperature 80.6° F

Example (Matrix 3200):

 

 

 

 

 

 

S

3.274.951.281.2212.0012.0612.12+080.600301302860

 

 

 

 

 

 

 

 

3.3 V power system at 3.27 V

Fan 1 rotating at 3,013 RPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: X2& = Voltage

 

 

Positive or negative voltage and magnitude

X2* = Temperature

 

 

Degrees Fahrenheit

 

 

 

X2( = Fan speed

 

 

In revolutions per minute (RPM)

 

 

 

 

 

 

 

 

 

 

 

FOX Matrix 3200 and 7200 Switchers • Programming Guide 66