Command and Response Table for SIS Commands
Symbol Definitions
] | = | CR/LF (carriage return/line feed) (hex 0D 0A) |
|
|
|
|
|
} | = | Carriage return (no line feed, hex 0D) |
|
|
|
|
|
= | Pipe (can be used interchangeably with the } character) |
|
|
| |||
• | = Space character |
|
|
|
|
| |
E | = Escape key (hex 1B) |
|
|
|
|
| |
W | = | Can be used interchangeably with the E character |
|
|
|
| |
X! | = | Input number (for tie) | 00 | – 32 | (FOX Matrix 3200) or 72 (FOX Matrix 7200) (00 = untied) | ||
X@ | = Output number | 01 | – 32 | (FOX Matrix 3200) or 72 (FOX Matrix 7200) | |||
X# | = Mute | 0 = not muted |
| 1 = muted | |||
X$ | = | SFP or reclockable output number | 00 – 32 or 72 (00 = global [SFP only]) |
| |||
X% | = | Output reclocking rate | 00 | = auto (default) |
| 01 = bypass | |
X^ | = | Laser control | 0 = disable | 1 = enable | 2 = automatic | ||
X& | = | Global preset # | 00 | – 32 | (3200) or 72 (7200) (00 = current configuration for view only) | ||
X* | = Room number (for room presets) | 01 | – 10 maximum (each can have up to 10 presets (X1)) assigned) | ||||
NOTE: A Room is a subset of
X( | = Name | Up to 12 characters for input and output names and global and room preset names | |
|
|
| Upper- and |
|
| ||
| NOTE: The following characters are invalid or not recommended in the name: ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?. | ||
|
|
|
|
X1) | = Room preset number | 01 – 10 maximum | |
NOTE: A Room preset is a stored configuration with all outputs in a single room. A retrieved room preset becomes the current configuration.
X1! = Connection status | 0 | = no input connected | 1 = input connected | ||
X1@ = | Group number (for I/O grouping) | 1 | (group 1) through 4 (group 4) (or 0 = no group) | ||
X1# = | Input number (for other than tie) | 01 – 32 (FOX Matrix 3200) or 72 (FOX Matrix 7200) | |||
X1$ = Lock mode status | 0 | = unlocked | 1 = locked | ||
X1% | = | Number (quantity) of inputs | 8, 16, 24, 32, 40, 48, 56, 64, or 72 |
| |
X1^ = | Number (quantity) of outputs | 8, 16, 24, 32, 40, 48, 56, 64, or 72 |
| ||
X1& = | Board installed | 0 = No board installed | 4 = | ||
|
|
| 1 = | 5 = | |
|
|
| 2 = | 6 = Pathological singlemode board | |
|
|
| 3 = 3G, SDI, | x = Unknown board or mix of transceivers | |
X1* | = I/O board slot number | 1 | – 9 (FOX Matrix 7200) or 1 – 4 (FOX Matrix 3200) | ||
X1( = | Transceiver module installed | 0 = No module installed |
| ||
|
|
| 1 | = | 3 = |
|
|
| 2 | = | 4 = Pathological singlemode module |
X2) | = | Transceiver module number | 01 – 72 (or maximum number of transceiver modules for your configuration) | ||
X2! = Vendor/manufacturer name |
|
|
| ||
X2@ = | Transmit output power in milliwatts |
|
|
| |
X2# = | Receive optical power in milliwatts |
|
|
| |
X2$ = SFP temperature | Degrees Celsius |
| |||
X2% = | Firmware version number to second decimal place (x.xx) |
| |||
X2^ = | Verbose firmware | ||||
X2& = | Voltage | Positive or negative voltage and magnitude |
| ||
X2* = Temperature | Degrees Fahrenheit |
| |||
X2( = | Fan speed | In revolutions per minute (RPM) |
| ||
* Legacy board, no longer manufactured, identified for | completeness only |
| |||
FOX Matrix 3200 and 7200 Switchers • Programming Guide 58