Chapter 6 Settings Menu
> 6.6 Remote Advanced Copy Configuration
ETERNUS DX400/DX8000 series ETERNUSmgr User Guide Settings/Maintenance
583 Copyright 2010 FUJITSU LIMITED
P2X0-0760-02ENZ0
4Click the [OK] button.
Returns to the [Menu] screen.
End of procedure

6.6.3.2 Initialize Advanced Copy Path

When there is no local path device configuration, only a Local Box ID, the local device's path
configuration is initialized. When initializing Advanced Copy path settings, first, delete the
Advanced Copy path configuration of the local device from the Path Configuration file according
to the procedure in "6.6.2.1 Edit Path Configurations" (page 548).
This section describes procedure to initialize the Advanced Copy Path settings.
Procedure
1Click [Set Advanced Copy Path] under the Remote Advanced Copy
Configuration in the [Settings] menu.
The [Set Advanced Copy Path (Initial)] screen appears.
Clicking the [Set REC Priority] link jumps to the initial screen of
the [Set REC Priority] function.
After normally completing the [Set Advanced Copy Path], set the
REC executing speed using the [Set REC Priority] function if you
want to use REC.
After normally completing the [Set Advanced Copy Path], use the
[Check Advanced Copy Path] function to confirm that the
Advanced Copy path of the Local device has been correctly set.