This response indicates that the error related to operation specification program occurs.
Byte 1 | Byte 2 | Byte 3 |
CNT | RPS | TEXT |
|
|
|
X'03' | X'55' | Detailed error Information I |
|
|
|
Detailed information I gives details on errors in command/response transmission and reception to and from the host computer.
b7 | b0 |
0 0
The dither pattern or the overlay pattern or γ pattern not registered was specified.
The bit or number of an undefined control register was spedcified.
An operation was specified for a nonexistent option.
Read area specification error (*1)
An undefined command was received.
Command sequence error
*1: Although standard document size bit on control register 5 is on, (Bit 7 takes "1" and bit 6 takes "0"), the size specifying bits (bits 0 to 4) are not defined.
Control register contents do not change even if the above errors are detected.
INTERFACE SPECIFICATIONS
M3099EX/EH OEM Manual |