X’0864' is set when the power is turned on or when a CLEAR command is issued for initialization.
b7 | b0 b7 | b0 |
#5
#6
0 0 0 0 1 0
(*1)
Magnification/vertical magnification (when each direction zooming is valid)
0 0 0 0 1 1 0 0 1 : 25%
to to 0 0 1 1 0 0 1 0 0 : 100%
Vertical/horizontal zooming specification (*2)
0 : Same magnification for both direction
1 : Different magnification for each direction
*1: Register A#5, #6, #7, and #8 must be sent consecutively.
*2: When the vertical/horizontal zooming specification is set to "0", the horizontal and vertical magnification is indicated. When this specification is set to "1", vertical magnification is specified at bit 0 of the register A#5 and at all bits of the register A#6.
Example
How to calculate the output resolution:
•Control register #1 is X'0B' (200 dpi)
•Image control register A#5 and A#6 are X '0819' (25%)
•Output resolution = 200 dpi × 0.25 = 50 dpi.