X'0000' is set when the power is turned on or when a CLEAR command is issued for initialization.
| b7 |
|
|
|
|
|
| b0 b7 |
|
|
|
|
|
| b0 | |||
#7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (*1) |
|
0 | 0 | 0 | 0 | 0 | 0 | 0 |
|
|
|
|
|
|
|
|
|
| ||
#8 |
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| INTERFACE | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SPECIFICATIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Horizontal magnification
(When each direction zooming is valid)
0 0 0 0 1 1 0 0 1 | : | 25% |
|
to |
| to |
|
0 0 1 1 0 0 1 0 0 | : | 100% | (*2) |
*1: Magnification is valid only when the horizontal/vertical zooming specification (bit 1 of the register A#5) is set to "1".
*2: Document magnification has the following limitations: Maximum main scanning data: 608 bytes/line
A × (B/400) × (C/100) | ≤ 608 (bytes) | |
8 | ||
|
A:Main scan width (unit: number of pixels when scanned at 400 dpi)
B:Basic resolution (set from operator panel or control register #0: 200, 240, 300, 400 dpi)
C:Horizontal magnification (25 to 100%)
This expression is rounded up to the integer.
Image control register B#5 to #8Since these registers are not supported, specify X’08000000'.