Control register A#1

Control register B#1

X’00' is set when the power is turned on or when a CLEAR command is issued for initialization.

b7

 

 

 

 

 

 

b0

INTERFACE

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

 

 

 

 

 

 

 

A#1

B#1

Density

00×××:

Set from the operator panel

01000:

Light

 

 

 

 

 

 

 

 

01001:

 

 

 

 

 

01010:

Somewhat light

 

 

Darken more

 

 

01011:

 

 

 

 

 

 

 

 

and more

01100:

Normal

 

 

 

 

(*3)

01101:

 

 

 

 

01110:

Somewhat dark

 

 

 

01111:

Dark

 

 

 

 

 

 

 

 

1××××:

Dynamic threshold (*1)

 

Linedrawing/photograph

0×: Set from the operator panel

10:Linedrawing (*2)

11:Photograph (*2)

*1: This function is valid for image processing circuit (IPC II) option. When the IPC II option is installed and these bits indicate IXXXX, the scanner applies the DTC function, and the function of the image control register are not operated.

*2 The scanning speed of ADF (sheets/min) in linedrawing mode is different from that of photograph mode.

*3: When the control resister #19, bit 0 is "0", eight types density are selectable by control register #1, bit 3 to 0.

And when the control register #19, bit 0 is "1", 256 types density are sellectable by the control register #20.

M3099EX/EH OEM Manual

3-27