RETURN SENSE command

Same as SENSE command. But the scanner does not report the temporary error.

Byte 1

Byte 2

Byte 3

CNT

CMD

or later

 

 

 

X'02'

X'42'

 

 

 

IMAGE MODE SENSE command

This command is valid for the scanner with the image processing circuit. When the scanner receives this command, the scanner reports the image processing mode of the main window and number of pixels (Unit: Byte) per line in the X-direction. By specification byte 3 of this command, the front or back-side image status can be selected.

Byte 1

 

Byte 2

 

 

 

Byte 3

 

CNT

 

CMD

 

 

 

TEXT

 

 

 

 

 

 

 

 

 

X'03'

 

X'43'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

5

4

3

2

1

0

0

 

0

0

0

0

0

0

0 : Front-side image status received

1 : Back-side image status received

INQUIRY command

When the scanner receives this command, the scanner reports a device information report.

Byte 1

Byte 2

CNT

CMD

 

 

X'02'

X'40'

 

 

3-52

M3099EX/EH OEM Manual