X”00" is set when the power is turned on or when a CLEAR command is issued for initialization.
| b7 |
|
|
|
|
|
| b0 |
#1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 | 0 | 0 | ||||||
|
|
|
|
|
|
|
|
|
Automatic separation specification (*1)
0 x : Set from the operator panel (*2)
1 0 : Automatic separation is not done.
1 1 : Automatic speparation
Conversion mode specification
0 x x : Not operation
1 0 0 : Not provided with white/black conversion. Not provided with right/left conversion.
1 0 1 : Not provided with white/black conversion. Provided with right/left conversion.
1 1 0 : Provided with white/black conversion. Not provided with right/left conversion.
1 1 1 : Provided with white/black conversion. Provided with right/left conversion.
Note: Image control registers #1 to #3 must be sent in one sequence. One of automatic separation, image emphasis, outline extract, overlay can be specified.
*1: Halftone specification (control register #2) is invalid in the automatic separation mode. However, halftone processing (dither or error diffusion) for photo area follows control register #19, and the dither pattern follows control register #2.
*2: When automatic separation specification is based on operator panel, the bit 7 of image control register #2 and the bit 3 of image control register #3 must be set to '0'.
M3099EX/EH OEM Manual |