48 At Screen 30, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 1 to 1999 sec. in 1 sec. step.)
49 Press [Mode 1] and [Mode 2] at a time to see Screen 29. The settings are stored to
EEPROM.
50 When you close the setup mode, go to 9 .
B3.16 Setting hopper timeWhen you set the hopper time, you must set as follows.
<< SETUP MODE >>
HOPPER TIMER
Screen 31
HOPPER TIMER
X X S
Screen 32
51 At Screen 2, press [Mode 1] sixteen times to go to the HOPPER TIMER screen. (Screen 31)
52 Press [Mode 2] to see Screen 32. (The default setting is 7 sec.)
53 At Screen 32, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 0 to 30 sec. in 1 sec. step.)
54 Press [Mode 1] and [Mode 2] at a time to see Screen 31. The settings are stored to
EEPROM.
55 When you close the setup mode, go to 9 .