APPENDIX
C
SEPARATION PRESSURE ADJUSTMENT
Adjust the separation pressure as follows:
WARNING
Wait at least 3 minutes after turning off the power before replacement.
ACHTUNG
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie mit dem Austausch beginnen.
Upper transport unit | Operator panel |
1 Turn off the power switch. Make sure that the hopper table is at the bottom.
2 Open the upper transport unit. (See page
Lever | Power switch |
Lever (green) | |
| 3 Disconnect the two relay |
| connectors on the roller ASY. |
| 4 Push the two levers (green) |
| towards each other to dis- |
| engage with the upper locking |
| holes and lower down the two |
Roller ASY | levers until they engage with |
the two levers locking holes. |
SEPARATION PRESSURE ADJUSTMENT
M3099EX/EH OEM Manual |