APPENDIX

C

SEPARATION PRESSURE ADJUSTMENT

Adjust the separation pressure as follows:

WARNING

Wait at least 3 minutes after turning off the power before replacement.

ACHTUNG

Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie mit dem Austausch beginnen.

Upper transport unit

Operator panel

1 Turn off the power switch. Make sure that the hopper table is at the bottom.

2 Open the upper transport unit. (See page 4-2)

Lever

Power switch

Lever (green)

 

3 Disconnect the two relay

 

connectors on the roller ASY.

 

4 Push the two levers (green)

 

towards each other to dis-

 

engage with the upper locking

 

holes and lower down the two

Roller ASY

levers until they engage with

the two levers locking holes.

SEPARATION PRESSURE ADJUSTMENT

M3099EX/EH OEM Manual

C-1