A#19

B#19

Control register A#18

Control register B#18

X”00" is set when the power is turned on or when a CLEAR command is issued for initialization.

• This register reserved for future.

 

 

 

 

 

 

 

 

 

INTERFACE

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

SPECIFICATIONS

A #18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

0

 

0

 

0

 

0

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

B #18

 

 

 

 

 

 

 

 

 

Control register A#19

Control register B#19

X’00' is set when the power is turned on or when a CLEAR command is issued for initialization.

b7

b0

0 0

Read density specification

0:8 steps (Control register #1 is valid.)

1:256 steps (Control register #20 is valid.)

Halftone processing method specification

0:Dithering

1:Error diffusion

γpattern number specification (*1)

0 0 0 : Normal

0 0 1 : Soft

0 1 0 : Sharp

0 1 1

1 0 0 : Three types (0 to 2) if the built-in 1 0 1 patterns are valid.

1 1 0 : Eight types (0 to 7) if the downloading 1 1 1 is enabled.

Download/built-in γ patterns

0:The patterns built into the device are valid.

1:The download patterns are valid.

*1: If the built-in patterns are valid, 0 to 2 ('000' to '010') can be selected.

M3099EX/EH OEM Manual

3-35