SEND DITHER 1 command
This command is valid for the scanner with the image processing circuit. By this command, download patterns of dither or overlay pattern can be registered.
Byte 1 | Byte 2 | Byte 3 | Byte 4 |
CNT | CMD | TEXT | or later |
|
|
|
|
X'43' | X'46' | Dither or overlay | Pattern data to |
|
| pattern number | be registered |
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | |||
| 0 |
| 0 |
| 0 |
| 0 |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
Dither and overlay pattern numbers (*1) 000 001
•
•
•
111 : Eight types
Dither and overlay specification 0 : Dithered
1 : Overlay
INTERFACE SPECIFICATIONS