1The CONTROL command can be issued more than once.

2The document size of *2 becomes the same as that reported by *1.

3No CONTROL command must be issued between a READ command for the front-side and a START command for the back-side. Any CONTROL command issued during this period is invalid. If a CONTROL command must be issued, terminate the scanning sequence once by issuing a CLEAR command. Issuing the CLEAR command cause the document to be ejected.

4The IMAGE MODE SENSE command need not always be issued.

5When a START command is received in the manual insertion mode, the Ready lamp lights whether the scanning start specification is “Operator Panel” or “Host”. The manual document insertion is awaited. When the Hopper Empty sensor is covered with a document, the scanner starts picking and transporting the document and returns “Normal Status”.

Figure 3.9 Command/response sequences for the read operation (3)

3-90

M3099EX/EH OEM Manual