Upper transport unit open
The upper transport unit was opened during ADF operation or the upper transport unit was open when ADF reading began.
ADF error
The roller unit wasn’t set when the hopper table was up, or document more than limitation was stacked on the hopper table.
Endorser error
When endorser use is specified and start command signal is received, either a printer head is not installed or a head error has occurred.
STOP button pressed
The Stop button was pressed during reading or while the scanner was waiting for the operator to press the Start button.
INTERFACE SPECIFICATIONS
This response indicates that the device fault occurs.
Byte 1 | Byte 2 | Byte 3 |
CNT | RPS | TEXT |
|
|
|
X'03' | X'50' | Detailed error Information III |
|
|
|
Detailed information III
Detailed error information III provides details of the scanner errors that require a call to CE.
b7 | b0 |
0
Hardware is blown.
The heater fuse is blown.
The print fuse is blown.
The stepper motor (ADF) fuse is blown.
The Lamp fuse is blown.
Optical error
Mechanical feeding error