When you reset the number to the initial number, you must see Section A2.4 of Appendix A.
B3.11 Reset of ink counterWhen you reset the ink counter, you must see Section A2.5 of Appendix A.
B3.12 Setting RS232C transfer rateWhen you set the RS232C transfer rate, you must set as follows.
<< SETUP MODE >>
RS232C BAUD
Screen 23
<<SETUP MODE >> 9600 : 4800 : 2400 : 1200
Screen 24
#1At Screen 2, press [Mode 1] twelve tmies to go to the RS232C BAUD screen. (Screen 23)
#2Press [Mode 2] to see Screen 24. (The default setting is 4800 bpsi)
#3At Screen 24, press [Mode 1] until the value you want to change blinks.
#4Press [Mode 2] to see Screen 23. The settings are stored to EEPROM.
#5When you close the setup mode, go to 9.
When you set the picking start time, you must set as follows.
<< SETUP MODE >>
PICK START TIMER
Screen 25
PICK START TIMER
X X . X S
Screen 26
#6At Screen 2, press [Mode 1] thirteen times to go to the PICK START TIME screen. (Screen 25)
#7Press [Mode 2] to see Screen 26. (The default setting is 1 sec.)
#8At Screen 26, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 0.2 to 29.8 sec. in 0.2 sec. step.)