Table 2.2 lists electrical specifications.
Table 2.2 Electrical specifications
Item | Specification | |
|
|
|
Input power | Voltage | 100 to 120 VAC/220 to 240 VAC ±10% |
|
|
|
| Phase | |
| Frequency | 50/60 Hz +2%, |
|
|
|
Power consumption | 0.25 kVA or less | |
|
|
|
Rush current | 30 A or less | |
Momentary power failure | 100%, 0.5 Hz | |
|
|
|
Leakage current | 3.5 mA or less | |
|
|
|
Dielectric strength | DC 1.8 KV for one minute or more | |
|
| (between FG and AC lines) |
AC line noise | Voltage 1.2 KV pulse duration 5 μs | |
|
|
|
Heat capacity | 110 Kcal/H (440 BTU/H) | |
|
|
|
Table 2.3 lists environmental specifications.
Table 2.3 Environmental specifications
Item |
| Specification |
|
|
|
|
|
Ambient | Device status | Operating | Not operating |
conditions |
|
|
|
Temperature | 5 to 35°C | ||
|
|
|
|
| Humidity | 20 to 80% | 8 to 95% |
|
| (no condensation) | (no condensation) |
Shock |
| 0.2 G less | 0.4 G or less |
|
|
|
|
Stability |
| 5° or less | 10° or less |
|
|
|
|
Acoustic noise | 59 dBA or less | 50 dBA or less | |
|
| (ISO 7779) | (ISO 7779) |
|
|
|
|
ESD |
| 8 KV or more |
|
|
|
|
|
M3099EX/EH OEM Manual |