Image control register A#2, B#2
X’00' is set when the power is turned on or when a CLEAR command state is issued for initialization.
b7 | b0 |
#2
Sharpness control (image emphasis)
0 0 0 | : | Normal |
|
|
0 0 1 | : | Emphasis, large | Sharp | |
0 1 0 | : | Emphasis, middle |
|
|
|
| |||
0 1 1 | : | Emphasis, small |
|
|
|
| |||
1 x x : | Smoothing | Soft |
Outline extraction control
0 0 : Outline extract
0 1 :
1 0 : Not defined
1 1 :
Sharpness, outline extraction specification
0 x x : Not operation
1 0 0 : Not operation
1 0 1 : Enables sharpness control.
1 1 0 : Enables outline extraction.
1 1 1 : Not defined
INTERFACE SPECIFICATIONS
M3099EX/EH OEM Manual |