Image control register A#2, B#2

X’00' is set when the power is turned on or when a CLEAR command state is issued for initialization.

b7

b0

#2

Sharpness control (image emphasis)

0 0 0

:

Normal

 

 

0 0 1

:

Emphasis, large

Sharp

0 1 0

:

Emphasis, middle

 

 

 

 

0 1 1

:

Emphasis, small

 

 

 

 

1 x x :

Smoothing

Soft

Outline extraction control

0 0 : Outline extract

0 1 :

1 0 : Not defined

1 1 :

Sharpness, outline extraction specification

0 x x : Not operation

1 0 0 : Not operation

1 0 1 : Enables sharpness control.

1 1 0 : Enables outline extraction.

1 1 1 : Not defined

INTERFACE SPECIFICATIONS

M3099EX/EH OEM Manual

3-41