Henny Penny 680 KFC manual Remove electrical power supplied to the fryer, Remove the Control Panel

Models: 680 KFC

1 109
Download 109 pages 54.87 Kb
Page 46
Image 46
2.Drain the shortening from the cookpot.

The Temperature Probe relays the actual shortening temperature to the control. If it becomes disabled, PROB will show in the display. Also, if the temperature is out of calibra- tion more than 10°F or C”, the probe should be replaced as follows:

1. Remove electrical power supplied to the fryer.

Place the Power Switch to the “OFF” position, and unplug the power cord or turn the wall circuit breaker off or electrical shock could result.

2.Drain the shortening from the cookpot.

3.Remove the Control Panel.

4.Remove probe connections from PC board.

5.Using a l/2” wrench, remove the nut on the compression fitting.

6.Remove the probe from the eookpot.

7.Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it extends one- half (l/2) inch (1.3 cm) into the cookpot, 5116inch (.78 cm) on gas fryers.

8.Tighten hand tight and then a half turn with wrench.

Excess force will damage probe.

9.Connect new probe to PC board and replace Control Panel.

10.Replace shortening.

11.Turn power “ON” and check out fryer.

Page 46
Image 46
Henny Penny 680 KFC manual Remove electrical power supplied to the fryer, Drain the shortening from the cookpot