Should the Control Panel not operate, replace the panel as follows:

 

PANEL - HENNY PENNY

 

1.

Remove electrical power supplied to the fryer.

 

 

 

 

 

Place the Power/Pump Switch in the “OFF” position, and

 

 

 

unplug the power cord and/or turn off the wall circuit breaker,

 

 

 

or electrical shock could result.

 

 

2.

Remove the two screws securing the Control Panel and lift

 

 

 

panel up and out.

 

 

3.

Unplug the connectors going to the Control Board.

 

 

4.

Install new Control Panel.

 

 

 

When plugging connectors into new Control Panel, be sure

 

 

 

connectors are lined-up correctly, such as, connector is not

 

 

 

plugged in backwards, or damage to the board could result.

 

 

 

5-8 PRESSURE REGULATION

 

The Henny Penny Fryer uses pressure as one of the components of

 

 

the cooking process. Once the lid is sealed to the cookpot, and the

 

 

solenoid valve closes, a deadweight valve maintains the correct

 

 

pressure in the cookpot.

 

 

The lid has minimal and limited maintenance and repair procedures,

 

 

which are addressed in the following sections.

 

 

The following is a routine maintenance schedule for the Lid:

 

 

Every 90 days

 

 

Clean and reverse lid gasket

 

 

Yearly Inspection

 

 

Remove and clean safety relief valve

 

 

Check Lid Gasket for splitting and tears - replace if necessary

 

 

Check Pressure Pads for wear - rotate if necessary

 

 

Check Cam Slide Guides - replace if worn or broken

 

 

Check Lid Rollers - replace if cracked or damaged.

5-6