Henny Penny | Model 680 |
SMS SPECIAL PROGRAM | Tech I/O Mode |
MODE (Continued) |
|
1. | Press and hold the Function button for two seconds until |
| “REG PROGRAM” shows in the display. As soon as |
| “REG PROGRAM” shows in the display, press and |
| release the Function button 4 times until “TECH |
| shows in the display. |
2. When “CODE” shows in the display, press | |
| “HEAT’, “PRESSURE”, and “PUMP” will show, alter- |
| nately, in the display. Also, the LEDs over 1, 2 and 3 |
| will flash alternately. |
3. | To test the heat circuit, press and hold the 1 button. |
4. | To test the pressure system, press and hold the 2 button. |
5. | To test the pump system, press and hold the 3 button. |
| Appliance Test |
| Press and hold the Function button for two seconds until |
| “REG PROGRAM” shows in the display. As soon as |
| “REG PROGRAM” shows in the display, press and |
| release the Function button 5 times until “APPL TEST” |
| shows in the display. |
| With the power switch on, the display will show |
| “CURR=”, along with the time it took the unit to heat |
| from 250º to 300º F (121ºto 149º C). This is normally |
| recorded from the initial heat up in the morning. |
| Heat Control |
1. | Press and hold the Function button for two seconds until |
| “REG PROGRAM” shows in the display. As soon as |
| “REG PROGRAM” shows in the display, press and |
| release the Function button 6 times until “HEAT |
| CNTRL” shows in the display. |
2. When “CODE” shows in the display, press
(82º C), and should not be changed until the factory is consulted.
1005 |