Model 680

SMS SPECIAL PROGRAM

Tech I/O Mode

MODE (Continued)

 

1.

Press and hold the Function button for two seconds until

 

“REG PROGRAM” shows in the display. As soon as

 

“REG PROGRAM” shows in the display, press and

 

release the Function button 4 times until “TECH I-O”

 

shows in the display.

2. When “CODE” shows in the display, press 2-4-6.

 

“HEAT’, “PRESSURE”, and “PUMP” will show, alter-

 

nately, in the display. Also, the LEDs over 1, 2 and 3

 

will flash alternately.

3.

To test the heat circuit, press and hold the 1 button.

4.

To test the pressure system, press and hold the 2 button.

5.

To test the pump system, press and hold the 3 button.

 

Appliance Test

 

Press and hold the Function button for two seconds until

 

“REG PROGRAM” shows in the display. As soon as

 

“REG PROGRAM” shows in the display, press and

 

release the Function button 5 times until “APPL TEST”

 

shows in the display.

 

With the power switch on, the display will show

 

“CURR=”, along with the time it took the unit to heat

 

from 250º to 300º F (121ºto 149º C). This is normally

 

recorded from the initial heat up in the morning.

 

Heat Control

1.

Press and hold the Function button for two seconds until

 

“REG PROGRAM” shows in the display. As soon as

 

“REG PROGRAM” shows in the display, press and

 

release the Function button 6 times until “HEAT

 

CNTRL” shows in the display.

2. When “CODE” shows in the display, press 1-2-3-4. “MELT”, “EXIT”, and “TEMP” will flash in the display, along with the shortening temperature at which the unit will exit the melt cycle. This should be set at 180º F

(82º C), and should not be changed until the factory is consulted.

1005

6-35

Page 108
Image 108