i CAUTION #

INIMUM PULLof equip- ment away from wall permissible for accessi- zk;ht’,” Quick Disconnect

DISCONNECT

BEFORE

MAXIMUM PULL

AVOID SHARP BENDS AND KINKS when pulling equipment away from wall. (Max- imum pull will kink ends, even if installed properly, and reduce Connector life.)

QUICK DISCON-

NECT DEVICE

while extended at

Please refer to the illustration below when installing cable restraint on all moveable gas fryers.

=ii

MAXIMUM PULL NOT ADVISED WHILE CONNECTED

Couplings and hose should be installed in the same plane as shown at left. DO NOT OFFSET COUPLINGS-this causes torsional twisting and undue strain causing premature failure.

This is the correct way to install metal hose for ver- tical traverse. Note the single, natural loop.

Allowing a sharp bend, as shown at right, strains and twists the metal hose to a point of early failure at the coupling.

Maintain the minimum or larger bending diameter between the couplings for longest life.

Closing in the diameter at the couplings, as shown at right, creates double bends causing work fatigue failure of the fittings.

In all installations where “self-draining” is not necessary, connect metal hose in a vertical loop.

DO NOT CONNECT

METAL HOSE HORI- ZONTALLY . . . unless “self-draining” is neces- sary, then use support on [zrr plane as shown at

l-bolt is to be secured to the building using acceptable building construc- tion practices.

i CAUTION #

ALL STR N

Secure l-bolt to a building stud. DO NOT attach to dry wall only. Also, locate the l-bolt at the same height as the gas service. Preferred installation is approximately six inches to either side of service. Cable restraint must be at least six inches shorter than flexible gas line.

L

Utilize elbows when necessary to avoid sharp kinks or excessive ben- ding. For ease of movement, install with a “lazy” loop. Gas appliance must be disconnected prior to max- imum movement. (Minimum move-

ment is permissible for hose disconnection).