Henny Penny |
| Model 680 |
| 3. | Clean inside of the elbow with hot water. |
OF SAFETY VALVE |
| NOTE |
(Continued) |
| Turn the relief valve towards the left side of the fryer |
|
| when reinstalling relief valve. |
| 4. | Immerse the safety relief valve in soapy water for 24 |
|
| hours. Use a 1 to 1 dilution rate. The valve cannot be |
|
| disassembled. It is factory preset to open at 14 1⁄2 pounds |
|
| of pressure. If it does not open or close, replace it! |
|
| DO NOT DISASSEMBLE OR MODIFY THIS VAVLE! |
|
| Tampering with this valve could cause serious injuries and |
|
| also voids agency approvals and appliance warranty. |
|
|
|
Calibration Steps | Recalibrate the pressure gauge if it is out of adjustment. | |
PRESSURE GAUGE | 1. | Remove the rim and glass. |
| 2. | If the indication hand shows a pressure or vacuum reading |
|
| when it should stand at “0”, turn the recalibrator screw in |
|
| the same direction in the indicating hand is to be moved |
|
| until the hand stands at proper “0” position. |
| 3. | Replace the rim and glass. |
Cleaning Steps | 1. | Remove the gauge and check inside the pipefittings from |
|
| dead weight body. Make certain fittings are clean and |
|
| open. |
| 2. | Clean and reinstall the gauge. |
1005 |