Product One |
| Pressure | Solenoid |
|
| and Neat | Control |
Select Time |
| Product | Indicators |
Select Function |
| Function | Indicators |
Change Button |
| Change Button | |
Under Display | 4 | Indicator | Display |
Change Button |
| Change Button | |
Under Display | 3 | Indicator | Display |
Change Button |
| Change Button | |
Under Display | 2 | Indicator | Display |
Change Button |
| Change Button | |
Under Display | 1 | Indicator | Display |
The SELECT FUNCTION or SELECT TIME button must be depressed before the PRODUCT ONE button to properly perform the solenoid and heat control output test.
For short durati | perate without | |
temperature | regulation, | or will overheat the |
shortening. |
|
|
When programming
-Load compensation adjusts cooking sate for differences in the cooking process such
as load size. The control is continuously comparing the pot temperature to the setpoint temperature. If the pot temperature is above the setpoint, the control will shorten the cook time. If the pot temperature is below the setpoint, the control will lengthen the cook time. Load compensation for KFC parameters is set at 0.
=Proportional control regulates pot the heat on and off until it reaches
setpoint temperature. This allows better temperature accuracy when dropping product. Proportional control for KFC parameters is set at 10 degrees.