SWAVeform Subsystem

CLRStat

CLRStat

Command:MACHine{12}:SWAVeform:CLRStat

The CLRStat command allows you to clear the waveform statistics without having to stop and restart the acquisition.

Example

OUTPUT XXX;":MACHINE1:SWAVEFORM:CLRSTAT"

 

 

Command

<number_of_ samples>

Example

Query

Returned Format

Example

DELay

:MACHine{12}:SWAVeform:DELay <number_of_samples>

The DELay command allows you to specify the number of samples between the State trigger and the horizontal center of the screen for the waveform display.

integer from -516096 to +516096 (HP 16554A) or from -1040384 to +1040384 (HP 16555A) or from -2080768 to +2080768 (HP 16555D)

OUTPUT XXX;":MACHINE2:SWAVEFORM:DELAY 127"

MACHine{12}:SWAVeform:DELay?

The DELay query returns the current sample offset value.

[MACHine{12}:SWAVeform:DELay] <number_of_samples><NL>

OUTPUT XXX;":MACHINE1:SWAVEFORM:DELAY?"

8–7