Selector

Example

SLISt Subsystem

SLISt

SLISt

:MACHine{12}:SLISt

The SLISt selector is used as part of a compound header to access those settings normally found in the State Listing menu. It always follows the MACHine selector because it selects a branch directly below the MACHine level in the command tree.

OUTPUT XXX;":MACHINE1:SLIST:LINE 256"

COLumn

Command:MACHine{12}:SLISt:COLumn <col_num> [,<module_num>,MACHine{12}],<label_name>,<base>

The COLumn command allows you to configure the state analyzer listing by assigning a label name and base to one of the 61 vertical columns in the menu. A column number of 1 refers to the leftmost column. When a label is assigned to a column it replaces the original label in that column.

When the label name is "TAGS," the TAGS column is assumed and the next parameter must specify RELative or ABSolute.

<col_num> integer from 1 to 61

<module_num> {12345678910}

<label_name> a string of up to 6 alphanumeric characters; "TAGS" to insert state or time tags.

<base> {BINaryHEXadecimalOCTalDECimalTWOSASCiiSYMBol IASSembler} for labels or

{ABSoluteRELative} for tags

Example

OUTPUT XXX;":MACHINE1:SLIST:COLUMN 4,’ADDR’,HEX"

 

 

7–7

Page 117
Image 117
HP 16555D, 16555A, 16554A manual COLumn, MACHine12SLISt