TWAVeform Subsystem

SPERiod

SPERiod

Command:MACHine{12}:TWAVeform:SPERiod <sample_period>

The SPERiod command allows you to set the sample period of the timing analyzer.

<sample_period> real number from 4 ns (HP 16554A) or 2 ns (HP 16555A/D) to 8 ms

Example

 

OUTPUT XXX;":MACHINE1:TWAVEFORM:SPERIOD 50E 9"

Query:MACHine{12}:TWAVeform:SPERiod?

The SPERiod query returns the current sample period.

Returned Format [:MACHine{12}:TWAVeform:SPERiod] <sample_period><NL>

Example

OUTPUT XXX;":MACHINE1:TWAVEFORM:SPERIOD?"

 

 

13–22

Page 220
Image 220
HP 16555A, 16555D, 16554A manual CommandMACHine12TWAVeformSPERiod sampleperiod, QueryMACHine12TWAVeformSPERiod?, 13-22