Programming Examples
Transferring the Logic Analyzer ConfigurationTransferring the Logic Analyzer Configuration
This program uses the SYSTem:SETup query to transfer the configuration of the logic analyzer to your controller. This program also uses the SYSTem:SETup command to transfer a logic analyzer configuration from the controller back to the logic analyzer. The configuration data will set up the logic analyzer according to the data. It is useful for getting configurations for setting up the logic analyzer by the controller. The SYSTem:SETup command differs from the SYSTem:DATA command because it only transfers the configuration and not acquired data.
10 ! ****************** SETUP COMMAND AND QUERY EXAMPLE ********************
20 !for the HP 16554A/HP 16555A/HP 16555D
30 !
40! ********************* CREATE TRANSFER BUFFER *************************
50! Create a buffer large enough for the block data. See "Sending Queries
51! to the Logic Analyzer" for how to calculate buffer size for data. This
52! buffer is only big enough for setup information.
53!
60ASSIGN @Buff TO BUFFER [320000]
70!
80! **************** INITIALIZE HPIB DEFAULT ADDRESS *********************
90!
100REAL Address
110Address=707
120ASSIGN @Comm TO Address
130!
140CLEAR SCREEN
150!
160! ************* INTITIALIZE VARIABLE FOR NUMBER OF BYTES *****************
170! The variable "Numbytes" contains the number of bytes in the buffer.
180!
190REAL Numbytes
200Numbytes=0
210!
220! **************
230!
240CONTROL @Buff,3;1
250CONTROL @Buff,4;0