Set Atten

 

 

 

 

 

Selftest (Full)

 

Function Group

SERVICE

 

Menu Map 6

 

Description

This softkey activates the self-test function of the synthesizer.

Programming Codes

SCPI: *TST?

 

 

Analyzer: NONE

 

See Also

Fault Menu, SCPI COMMAND SUMMARY

 

 

“OPERATOR’S CHECK and ROUTINE MAINTENANCE,”

 

 

Chapter 4.

Set Atten

Function Group

Menu Map

Description

Programming Codes

POWER

I

5

This softkey lets you set the attenuator separately from the rest of the ALC system. When an entry is made using this key, the attenuator is automatically uncoupled from the ALC system, so that the [POWER LEVEL) key controls the ALC system apart from the attenuator.

SCPI: POWer:ATTenuation <num>[DB] or

MAXimum]MINimum]UP]DOWN

Analyzer: SHLS <num>[DB]DM]

See Also (ALC), ( P O W E R L E V E L ) , Uncoupl Atten

“Working with Mixers/Reverse Power Effects,” in Chapter 1.

HP 8360

Operating and Programming Reference S-59

User’s Handbook