SCPI COMMAND SUMMARY

 

 

MARKer[n]:MODE

How the frequency of the marker is determined.

FREQuency

Absolute frequency is used. The limits are

 

confined to the present START and STOP

 

frequency limits.

DELTa

The value is specified with respect to the

 

reference marker. (MARKer[n]:REFerence)

 

 

The *RST values are the same as the FREQ : CENTcommand *RST value.

MARKer EnI : MODE FREQuency I DELTa

MARKer [n] : MODE?

Sets and queries the mode of the specified marker. Setting one marker to delta turns all other marker modes to frequency. If [n] is not specified, the default is one. *RST value is FREQuency.

MARKer [n] : REFerence <r-r>

MARKer [nl : REFerence?

Sets and queries which marker is the reference marker for use in the delta mode. While [n] may be used, there is really only a single reference for all the markers. MARKerl :REFerence 5; and MARKer2:REFerence 5; both set marker 5 as the reference.

MARKer [n] [ : STATeI ON OFF 1 O

MARKer [n] [ : STATe] ?

The state of the specified marker is set and queried (marker number one if [n] is not specified). The *RST value for all markers is OFF.

MEASure : AM?

A query-only command that causes the modulating AM signal to be measured and the absolute value of the peak percent deviation to be returned.

a MEASure : FM

A query-only command that causes the modulating FM signal level to be measured and the corresponding peak frequency deviation returned.

MODulation:OUTPut:SOURceAMIFM

MODulation:OUTPut:SOURce?

Sets and queries the source of the rear panel output modulation

BNC.

MODulation:OUTPut:STATe ONlOFFlllO

MODulation:OUTPut:STATe?

Sets and queries the state of the rear panel output modulation BNC.

HP 8360

Operating and Programming Reference S-41

User’s Handbook

 

Page 339
Image 339
HP 8360 manual Bnc