Synthesized Step Sweep

Accuracy: Same as time base

Minimum Step Size: Same as frequency resolution

Number of Points: 2 to 801

Switching Time: Same as CW

Dwell Time: 100 ps to 3.2 s

Synthesized List Mode Accuracy: Same as time base

Minimum Step Size: Same as frequency resolution

Number of Points: 1 to 801

Switching Time: Same as CW

Dwell Time: 100 ~LS to 3.2 s

Ramp Sweep Mode Accuracy2 (sweep time 2 100 ms and 5 5 s):

Sweep Widths 5 n x 10 MHz: 0.1% of sweep width f time base accuracy.

Sweep Widths > n x 10 MHz: Lesser of 1% of sweep width or n x 1 MHz + 0.1% of sweep width.

Sweep Time: 10 ms to 100 seconds, 300 MHz/ms maximum rate

Internal 10 MHz Time Base

Accuracy: Calibration f Aging Rate f Temperature Effects f Line Voltage Effects

Stability

Aging Rate: 5 x lo-lo/day, 1 x 10e7/year

With Temperature: 1 x 10-‘“/oC, typical

With Line Voltage: 5 x 10 -lo for line voltage change of lo%, typical

2 Sweeptime 1 150 ms and 5 5 s for Option 006 instruments.

Specifications