Warning Temperature Alarm

Raise Alarm When Temperature (°C) Reaches. Specify this option to trigger an alarm

 

when the CPU temperature exceeds the rising threshold. When the CPU returns to the

 

reset threshold, the rising alarm is cleared. When the CPU returns to the reset threshold,

 

the rising alarm is cleared. The default value for the rising threshold temperature is 70º

 

C; the default reset threshold temperature is 67º C.

 

 

 

Rising Threshold. Specify the rising temperature (º C).

 

 

 

Reset Threshold. Specify the reset temperature (º C).

 

 

Additional Alarms

Raise Alarm When Network Interface Duplex Errors are Detected. Specify this

 

option to trigger an alarm if the system has encountered a large number of packet errors

 

in your network. Make sure the speed and duplex settings on your HP EFS WAN

 

Accelerator match the settings on your switch and router.

 

This alarm is enabled by default.

 

 

 

Raise Alarm When Network Interface Link Errors are Detected. Specify this option

 

to trigger an Simple Network Management Protocol (SNMP) trap, email, and alarm

 

notification when a link goes down. This alarm is disabled by default.

 

For WAN/LAN interfaces, an alarm is only triggered if in-path support is enabled for that

 

WAN/LAN pair.

 

 

 

Raise Alarm When Extended Memory Paging Activity is Detected. Specify this

 

option to trigger the memory paging alarm. If 100 pages are swapped every couple of

 

hours, the HP EFS WAN Accelerator is functioning properly. If thousands of pages are

 

swapped every few minutes, contact HP Technical Support.

 

This alarm is enabled by default.

 

 

 

Raise Alarm If a Software Version Mismatch is Detected in the Network. Specify

 

this option to trigger an alarm if there is a mismatch between software versions in the HP

 

EFS WAN Accelerator system.

 

This alarm is enabled by default.

 

 

2 CONFIGURING THE HP EFS WAN ACCELERATOR

Setting Email Notification

4.Click Apply to apply your settings to the running configuration. (Apply your settings to test a new configuration before saving them permanently.)

5.Click Save to save your settings permanently or click Reset to return the settings to their previous values.

You can set email notification parameters for events and failures in the Reports - Notification page.

By default email addresses are not specified for event and failure notification.