HP Enterprise File Services WAN Accelerator Viewing Appliance Reports, Viewing Data Store Reports

Models: Enterprise File Services WAN Accelerator

1 232
Download 232 pages 61.98 Kb
Page 162
Image 162

 

3. Use the controls to customize the report, as described in the following table..

 

 

Control

Description

 

 

Period

Select Last Hour, Last Day, Last Week, or Last Month from the drop-down list.

 

 

Type

Select Optimized, Pass-Through, or Both from the drop-down list. The default value is

 

Optimized.

 

 

Refresh

Set a rate to refresh the report display:

 

• To refresh your report every 15 seconds, click 15 Seconds.

 

• To refresh your report every 30 seconds, click 30 Seconds.

 

• To turn off refresh, click Off.

 

NOTE: The refresh rate does not affect polling. Polling occurs every 5 minutes.

 

 

Printer icon

To print your report, click the Printer icon in the upper right corner of the page.

 

 

Viewing Data Store Reports

162

Viewing Appliance Reports

The following section describes how to create and view appliance reports. It includes the following sections:

‹“Viewing Data Store Reports,” next

‹“Viewing TCP Statistics Report” on page 163

The Appliance - Data Store report summarizes the current status and state of the data store synchronization process.

If you have enabled data store synchronization, it summarizes the state of the replication process. For detailed information, see “Enabling Failover and Data Store Synchronization” on page 73.

The Appliance - Data Store report contains the following table that summarizes the current state of the data store in the appliance.

Field

Description

 

 

Synchronization Connection

Specifies the current connection status of the data store.

Status

 

 

 

Synchronization Catch-Up

Specifies the process of transferring the newest data in from

Status

the active HP EFS WAN Accelerator to the passive HP EFS

 

WAN Accelerators. The process is complete when the Catch

 

Up and Keep Up processes meet.

 

 

Synchronization Keep-Up

Specifies the process of over-writing the oldest part of the

Status

data store and proceeding to the newest part of the data store.

 

The process is complete when the Catch Up and Keep Up

 

processes meet.

 

 

Data Store Percentage Used

Specifies the percentage of the data store that is available for

(Since Last Clean)

optimization since the last data store clean request.

 

 

CREATING HP EFS WAN ACCELERATOR REPORTS AND LOGS

Page 162
Image 162
HP Enterprise File Services WAN Accelerator manual Viewing Appliance Reports, Viewing Data Store Reports, Optimized, 162