HP Enterprise File Services WAN Accelerator manual and Starting and Stopping Services on, 187

Models: Enterprise File Services WAN Accelerator

1 232
Download 232 pages 61.98 Kb
Page 187
Image 187

What This Report Tells You

Alarm

Description

 

 

Proxy File Service

Whether there has been a PFS connection error. If a connection error

Connection Error

is detected, restart the HP EFS WAN Accelerator service and PFS.

 

For detailed information, see “Enabling Proxy File Service” on

 

page 99 and “Starting and Stopping Services” on page 144.

 

 

Proxy File Service

Whether a synchronization operation has failed. If an operation

Operation Failed

failure is detected, attempt the operation again. For detailed

 

information, see “Adding PFS Shares” on page 102.

 

 

Redundant Array of

Whether the system has encountered RAID errors (for example,

Independent Disks

missing drives, pulled drives, drive failures, and drive rebuilds).

(RAID)

For drive rebuilds, if a drive is removed and then reinserted, the

 

 

alarm continues to be triggered until the rebuild is complete.

 

IMPORTANT: Rebuilding a disk drive can take 4-6 hours.

 

NOTE: RAID status applies only to the HP EFS WAN Accelerator,

 

Series 3000 and 5000.

 

 

Software Version

Whether there is a mismatch between software versions in your

Mismatch

network. If a software mismatch is detected, resolve the mismatch by

 

upgrading or reverting to a previous version of the software. For

 

detailed information, see “Upgrading Your Software” on page 142.

 

NOTE: If a software version mismatch occurs and you are running

 

v.1.2 and client-side v.2.1 HP EFS WAN Accelerators, you must set

 

the correct version of the HP EFS WAN Accelerator service protocol

 

on the client-side v.2.1 appliances using the HP EFS WAN

 

Accelerator CLI:

 

sh> peer <addr> version min 5

 

sh> peer <addr> version max 5

 

 

System Disk Full

Whether the data store has reached maximum disk capacity.

 

 

Temperature

Whether the CPU temperature has exceeded the critical threshold.

 

The default value for the rising threshold temperature is 70º C; the

 

default reset threshold temperature is 67º C.

 

 

The Health -Alarm Status report answers the following question:

‹What is the current status of the HP EFS WAN Accelerator?

3 CREATING HP EFS WAN

ACCELERATOR REPORTS AND

HP STORAGEWORKS EFS WAN ACCELERATOR MANAGEMENT CONSOLE USER GUIDE

187

Page 187
Image 187
HP Enterprise File Services WAN Accelerator manual and Starting and Stopping Services on, 187