Setting Alarm Parameters

To set alarm parameters

You can set alarms in Reports - Alarm Settings page.

Enabling alarms is optional.

1.Click the Setup tab to display the Setup menu.

2.Click Reports to display the Reports - Alarm Settings page.

Figure 2-47.Reports - Alarm Settings Page

3.Use the controls to complete the configuration, as described in the following table.

Control

Description

 

 

CPU Alarms

Raise Alarm When CPU Utilization Reaches. Specify this option to trigger an alarm if

 

the average and peak threshold for the Central Processing Unit (CPU) utilization is

 

exceeded. When an alarm reaches the rising threshold, it is activated; when it reaches the

 

lowest or reset threshold, it is reset. After an alarm is triggered, it is not triggered again

 

until it has fallen below the reset threshold.

 

This alarm is enabled by default, with a rising threshold of 90% and a reset threshold of

 

70%.

 

 

 

Rising Threshold. Specify rising value CPU utilization.

 

 

 

Reset Threshold. Specify reset value for CPU utilization.

 

 

Data Store Alarm

Send email if stale data replaced by fresh data is less than __ day(s) old. Specify this

 

option to trigger an alarm if data in the data store is replaced with new data before the

 

time period specified.

 

 