HP Integrity Server rx4640 manual Replacing the QuickFind Diagnostic Board

Models: Integrity Server rx4640

1 197
Download 197 pages 32.12 Kb
Page 110
Image 110

Removing and Replacing Components

Removing and Replacing the QuickFind Diagnostic Board

Step 5. Unplug the cable from the connector on QuickFind diagnostic board and remove the board from the chassis. Figure 4-45 shows how to remove the QuickFind diagnostic board.

Figure 4-45 Removing and Replacing the QuickFind Diagnostic Board

Cover

QuickFind diagnostic board

Replacing the QuickFind Diagnostic Board

To replace the QuickFind diagnostic board, follow these steps:

Step

1.

Gently plug the cable into the QuickFind diagnostic board connector.

Step

2.

Replace the QuickFind diagnostic board into the cover by snapping it into place.

Step

3.

Turn the assembly over and snap into place on top of the power supply cage.

Step

4.

Replace the top cover. See “Replacing the Top Cover” on page 44.

Step

5.

If rack mounted, slide the HP server into the rack until it stops. See “Inserting the Server into the

 

 

Rack” on page 39.

110

Chapter 4

Page 110
Image 110