Troubleshooting

Troubleshooting Using LED Indicators

Table 5-4

QuickFind Diagnostic Panel LED Definitions (Continued)

 

 

 

 

 

 

Item

LED 0

LED 1

LED 2

LED3

Details

 

 

 

 

 

 

Subsystem

CPU

Memory

I/O

n/a

A soldered voltage regulator has failed—the

 

board

board

board

 

specified board must be replaced.

 

 

 

 

 

 

I/O VRM

12 volt

5 volt

3 volt

n/a

A plug-in voltage regulator has

 

 

 

 

 

failed—replace I/O baseboard.

 

 

 

 

 

 

CPU VRM

n/a

n/a

n/a

n/a

n/a

 

 

 

 

 

 

Fan Module

0

1

2

n/a

One or both fans in a fan module have

 

 

 

 

 

failed—the module must be replaced.

 

 

 

 

 

Fan 2 is in front of the power supplies.

 

 

 

 

 

 

Memory

DIMM

DIMM

DIMM

DIMM

The specified DIMM has failed—the DIMM

Bank X (0-7)

xA

xB

xC

xD

must be replaced.

 

 

 

 

 

If all the LEDs for a rank (0-7) are lit and

 

 

 

 

 

the memory config error LED is lit, then the

 

 

 

 

 

DIMMs in the specified rank are

 

 

 

 

 

mismatched—replace mismatched DIMM.

 

 

 

 

 

 

Check

n/a

n/a

n/a

 

One of the power supply or power supply

Power

 

 

 

 

fans have failed—replace the power supply.

Supply

 

 

 

 

The faulty power supply LED (located on

 

 

 

 

 

Power supply) will be lit.

 

 

 

 

 

 

Memory

n/a

n/a

n/a

 

The DIMMs in a rank are mismatched. All

Config Error

 

 

 

 

the DIMMs in the specified rank (0-7) will

 

 

 

 

 

be lit.

 

 

 

 

 

 

Processor

n/a

n/a

n/a

 

The processors are mismatched—replace

Config Error

 

 

 

 

mismatched processor.

 

 

 

 

 

 

Missing

n/a

n/a

n/a

 

A required component(s) is not installed in

Component

 

 

 

 

the server and thus preventing “power-up.”

 

 

 

 

 

 

Server Temp

n/a

n/a

n/a

 

The internal temperature of the server has

 

 

 

 

 

exceeded the warning or critical level.

 

 

 

 

 

 

Check Event

n/a

n/a

n/a

 

An event has occurred that requires

Log

 

 

 

 

attention.

 

 

 

 

 

 

120

Chapter 5

Page 120
Image 120
HP Integrity Server rx4640 manual 120