HP Integrity Server rx4640 manual Replacing a Hot-Swap Power Supply

Models: Integrity Server rx4640

1 197
Download 197 pages 32.12 Kb
Page 99
Image 99

 

 

Removing and Replacing Components

 

 

Removing and Replacing the Power Supplies

Step

3.

Loosen the captive thumbscrew located at the top left of the PSU.

Step

4.

Grasp the handle and pull the PSU out of the server. Figure 4-40 shows how to remove a PSU.

Replacing a Hot-Swap Power Supply

Step

1.

Supporting the PSU with both hands, slide it into the empty slot until it plugs into the socket on

 

 

the internal power distribution board. Tighten the thumbscrew hand-tight.

Step

2.

Install the power cord into the PSU socket.

Step

3.

Apply power to the new PSU and the LED should immediately turn on.

Step

4.

If rack mounted, slide the HP server back into the rack until it stops. “Inserting the Server into the

 

 

Rack” on page 39.

Figure 4-40 Removing and Replacing the Hot-Swap Power Supply

Chapter 4

99

Page 99
Image 99
HP Integrity Server rx4640 manual Replacing a Hot-Swap Power Supply, Removing and Replacing the Hot-Swap Power Supply