HP Integrity Server rx4640 manual Power Supply Status LED Indicators

Models: Integrity Server rx4640

1 197
Download 197 pages 32.12 Kb
Page 123
Image 123

Troubleshooting

Troubleshooting Using LED Indicators

Power Supply Status LED Indicators

Each of the two 200-240 VAC power supply unit has three status LEDs located on the back of the power supply on the rear panel. Consolidated status of all power supplies is reported by the front control panel by the power status LED.

Figure 5-6 Power Supply Status LED

Predict Fail LED-Amber

Power LED-Green

Fail LED-Amber

Table 5-6

Power Supply Status LED

 

 

 

 

Power

Predict Fail

Fail

Status

LED-Green

LED-Amber

LED-Amber

 

 

 

 

 

Off

Off

Off

No ac power applied to all PSUs.

 

 

 

 

Off

Off

On

No ac power applied to this PSU only.

 

 

 

 

Blinking

Off

Off

ac present/standby outputs on.

 

 

 

 

On

Off

Off

PSU dc outputs on and OK.

 

 

 

 

Off

Off

On

Power supply failure.

 

 

 

 

On

Blinking

Off

Predictive failure—PSU about to fail because of poorly

 

 

 

performing fan.

 

 

 

 

On

Off

Blinking

Current limit on 48 VDC output.

 

 

 

 

iLO MP LAN Port Link/Activity LED Display

The iLO MP LAN uses an RJ-45 type connector. This connector has two LEDs (LAN link and LAN activity) that signal status and activity.

Two versions of the iLO MP card exist for this server. Depending on which version of the card is installed in the server, the iLO MP LAN port LEDs display differently.