Table 5. Troubleshooting (continued)

Problem

 

 

 

indicator

Component

Possible cause

Possible solutions

 

 

 

 

Amber and green

Power supply

Power supply failure

Replace the failed power supply.

LEDs are lit

(fault and

 

 

 

 

 

 

power LEDs

 

 

 

are lit)

 

 

 

 

 

 

All amber and

All drives

Check for and solve one of the following situations:

green LEDs are

(activity and

v Storage expansion enclosures are not correctly

slowly flashing

connected to the DS3200.

 

fault LEDs are

 

v DS3200 does not have the correct firmware version.

 

not lit)

 

 

 

 

All green LEDs

All components

Subsystem power is

Make sure that all storage

are off

 

off.

subsystem power cables are

 

 

 

connected and that the

 

 

 

power-supply switches are on. If

 

 

 

applicable, make sure that the

 

 

 

main circuit breakers for the rack

 

 

 

are turned on.

 

 

 

 

 

 

AC power failure

Check the main circuit breaker

 

 

 

and ac receptacle.

 

 

 

 

 

 

Power-supply failure

Replace the power supply.

 

 

 

 

Amber LED is

Drives (fault

Drive identify is in

No corrective action is needed.

flashing

LED is lit)

process

 

 

 

 

 

One or more

Power supplies

Power cable is

Make sure that the power cord is

green LEDs are

 

disconnected or

connected and that the switches

off

 

switches are turned

are turned on.

 

 

off

 

 

 

 

 

 

All drives

Midplane failure

Replace the DS3200. Contact

 

 

 

your IBM technical-support

 

 

 

representative.

 

 

 

 

 

Several

Hardware failure

Replace the affected

 

components

 

components. If this does not

 

 

 

correct the problem, replace the

 

 

 

RAID controllers. Contact your

 

 

 

IBM technical-support

 

 

 

representative.

 

 

 

 

 

 

The DS3200 was

Perform one of the following

 

 

not powered-on, or

actions:

 

 

all SAS cable

v Power-on the storage

 

 

connections

subsystem.

 

 

between the storage

 

 

v Make sure that the SAS cable

 

 

expansion

connections between the

 

 

enclosures and the

 

 

storage expansion enclosures

 

 

DS3200 storage

 

 

and the DS3200 storage

 

 

subsystem failed.

 

 

subsystem are made.

 

 

 

 

 

 

 

 

Front panel

Power supply

Make sure that the power cables

 

 

problem

are connected and that the power

 

 

 

supplies are turned on.

 

 

 

 

 

 

Hardware failure

If any other LEDs are lit, replace

 

 

 

the midplane. Contact your IBM

 

 

 

technical-support representative.

 

 

 

 

Chapter 6. Solving problems 101

Page 119
Image 119
IBM DS3200 Storage Subsystem manual Solving problems