Controller

Controller Storage subsystems

Ethernet

Host computer

SAS I/O path

Management station

(one or more)

Figure 25. Direct (out-of-band) managed storage subsystems

Installing the storage subsystem configuration

Using the information from the previous sections, install the host systems and host bus adapters (HBAs).

Notes:

1.See the documentation that comes with the HBAs for installation requirements and procedures.

2.Use the correct HBA device driver. For the latest supported HBAs and device drivers, go to http://www.ibm.com/servers/storage/support/disk/

Attach a SAS cable to each HBA. Continue to “Connecting hosts to the DS3200” to connect the other end of each cable to a controller.

Connecting hosts to the DS3200

The DS3200 can support up to fourteen hosts when attached to the SAS Connectivity Module for IBM BladeCenter and up to three hosts in a direct attached host environment. The number of supported hosts depends on the number of host ports installed on the DS3200 RAID controller. To protect against the loss of any one path from the host servers to the DS3200 storage subsystem, use redundant host connections.

Note: In a single-controller storage subsystem, the use of redundant host connections is possible only when the optional SAS host port adapter is installed in the controller. This provides path failover but limits the number of redundant host connections to one.

Chapter 3. Cabling the storage subsystem 37

Page 55
Image 55
IBM DS3200 Storage Subsystem manual Installing the storage subsystem configuration, Connecting hosts to the DS3200