4. Remove the controller from the chassis.

Handle

Guide pin

Notch

Figure 42. Removing and replacing controller A

a.On the left side of the controller, press the orange release tab to the right just enough to release the handle; then, rotate the handle upward.

b.Slowly pull the handle away from the chassis to remove the controller from the bay, as shown in Figure 42.

c.Turn over the controller and lay it on a flat, static-protective surface.

5.Remove the two screws that connect the SAS host port adapter filler panel to the controller and lift the filler panel out of the controller. Set the screws aside.

SAS host port adapter filler panel

Screws

Figure 43. Removing the SAS host port adapter filler panel

6.Touch the static-protective package that contains the SAS host port adapter to any unpainted metal surface on the DS3200; then, remove the adapter from the package.

70System Storage DS3200 Storage Subsystem: Installation, User’s, and Maintenance Guide

Page 88
Image 88
IBM DS3200 Storage Subsystem manual Removing and replacing controller a